Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.637
Filtrar
1.
Invest Ophthalmol Vis Sci ; 65(4): 20, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38587439

RESUMO

Purpose: Axenfeld-Rieger syndrome (ARS) is characterized by ocular anomalies including posterior embryotoxon, iridocorneal adhesions, corectopia/iris hypoplasia, and developmental glaucoma. Although anterior segment defects and glaucoma contribute to decreased visual acuity, the role of potential posterior segment abnormalities has not been explored. We used high-resolution retinal imaging to test the hypothesis that individuals with ARS have posterior segment pathology. Methods: Three individuals with FOXC1-ARS and 10 with PITX2-ARS completed slit-lamp and fundus photography, optical coherence tomography (OCT), OCT angiography, and adaptive optics scanning light ophthalmoscopy (AOSLO). Quantitative metrics were compared to previously published values for individuals with normal vision. Results: All individuals demonstrated typical anterior segment phenotypes. Average ganglion cell and inner plexiform layer thickness was lower in PITX2-ARS, consistent with the glaucoma history in this group. A novel phenotype of foveal hypoplasia was noted in 40% of individuals with PITX2-ARS (but none with FOXC1-ARS). Moreover, the depth and volume of the foveal pit were significantly lower in PITX2-ARS compared to normal controls, even excluding individuals with foveal hypoplasia. Analysis of known foveal hypoplasia genes failed to identify an alternative explanation. Foveal cone density was decreased in one individual with foveal hypoplasia and normal in six without foveal hypoplasia. Two individuals (one from each group) demonstrated non-foveal retinal irregularities with regions of photoreceptor anomalies on OCT and AOSLO. Conclusions: These findings implicate PITX2 in the development of the posterior segment, particularly the fovea, in humans. The identified posterior segment phenotypes may contribute to visual acuity deficits in individuals with PITX2-ARS.


Assuntos
Segmento Anterior do Olho/anormalidades , Doenças da Córnea , Anormalidades do Olho , Oftalmopatias Hereditárias , Glaucoma , Humanos , Retina , Anormalidades do Olho/diagnóstico por imagem , Anormalidades do Olho/genética , Oftalmopatias Hereditárias/diagnóstico , Oftalmopatias Hereditárias/genética , Glaucoma/diagnóstico , Glaucoma/genética
2.
Rom J Ophthalmol ; 68(1): 60-64, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38617728

RESUMO

Aim: To present a complex case of Ahmed tube exposure 6 months after the implantation associated with corneal melting and iris prolapse, and the surgical reposition that required multiple allografts and limbal reconstruction. Methods: A 60-year-old patient arrived at the emergency room with tube exposure combined with corneal melting and iris prolapse from a previously placed Ahmed valve 6 months prior. Our approach was to use one corneoscleral graft to repair the melted cornea and avoid further iris prolapse and a second scleral graft to cover the repositioned tube. Upon completion of conjunctival dissection, cleaning and deepithelization of the melted cornea and the tube by application of alcohol 100% followed. A new entry point was made for the tube and was covered using an alcohol-preserved scleral allograft and the previous entry point was repaired using a corneoscleral allograft with the corneal aspect restoring the limbus and avoiding further iris protrusion. Results: 6 months follow-up of the patient showed excellent recovery, anatomical restoration, and IOP normalization. Conclusion: Surgical repair of these cases can be very demanding, and requires surgical improvisation and prolonged surgical time. The literature remains very limited on how a surgeon should approach similar cases, which are the crucial tips, and which are the missteps that should be avoided. In this case, we used multiple scleral/corneoscleral allografts in a specific orientation and different sutures to reconstruct the damaged limbal area and restore the anatomy. Abbreviations: VA = Visual Acuity, GDD = Glaucoma Drainage Device, IOP = Intra Ocular Pressure.


Assuntos
Úlcera da Córnea , Glaucoma , Humanos , Pessoa de Meia-Idade , Glaucoma/complicações , Glaucoma/diagnóstico , Córnea , Iris , Etanol , Aloenxertos
3.
Transl Vis Sci Technol ; 13(4): 21, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38619925

RESUMO

Purpose: The purpose of this study was to explore risk factors for symptomatic presbyopia, defined as near add power ≥1.50 diopters, in patients with glaucoma. Methods: Treated glaucoma (n = 56), untreated glaucoma (n = 21), and control individuals (n = 376), aged 40 to 55 years at first visit, were enrolled in the study, and near add power, retinal thickness, and visual field were examined. The association between near add power and ocular parameters and the odds ratios (ORs) for symptomatic presbyopia were investigated. Survival analysis for symptomatic presbyopia was conducted. Results: Age, astigmatic power, mean deviation, and ganglion cell complex thickness were associated with near add power. The OR for symptomatic presbyopia was significant for age (OR = 1.51), astigmatism (OR = 1.01), mean deviation (OR = 0.72), ganglion cell complex thickness (OR = 0.98), treated and untreated glaucoma (OR = 2.09), and use of glaucoma eye drops (OR = 3.33). Survival analysis showed that the treated glaucoma group reached the near add power endpoint of ≥1.50 D (symptomatic presbyopia) significantly earlier than the other two groups, and there was no difference between the control and untreated glaucoma groups. Conclusions: Glaucoma patients treated with eye drops may start near correction earlier. Translational Relevance: Symptomatic presbyopia may develop earlier in patients with glaucoma, and our findings could further contribute to better management and understanding of presbyopia with glaucoma.


Assuntos
Glaucoma , Presbiopia , Humanos , Presbiopia/epidemiologia , Estudos Retrospectivos , Acuidade Visual , Estudos Transversais , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Soluções Oftálmicas
4.
Transl Vis Sci Technol ; 13(4): 15, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38591945

RESUMO

Purpose: The purpose of this study was to estimate the distribution of the true rates of progression (RoP) of visual field (VF) loss. Methods: We analyzed the progression of mean deviation over time in series of ≥ 10 tests from 3352 eyes (one per patient) from 5 glaucoma clinics, using a novel Bayesian hierarchical Linear Mixed Model (LMM); this modeled the random-effect distribution of RoPs as the sum of 2 independent processes following, respectively, a negative exponential distribution (the "true" distribution of RoPs) and a Gaussian distribution (the "noise"), resulting in a skewed exGaussian distribution. The exGaussian-LMM was compared to a standard Gaussian-LMM using the Watanabe-Akaike Information Criterion (WAIC). The random-effect distributions were compared to the empirical cumulative distribution function (eCDF) of linear regression RoPs using a Kolmogorov-Smirnov test. Results: The WAIC indicated a better fit with the exGaussian-LMM (estimate [standard error]: 192174.4 [721.2]) than with the Gaussian-LMM (192595 [697.4], with a difference of 157.2 [22.6]). There was a significant difference between the eCDF and the Gaussian-LMM distribution (P < 0.0001), but not with the exGaussian-LMM distribution (P = 0.108). The estimated mean (95% credible intervals, CIs) "true" RoP (-0.377, 95% CI = -0.396 to -0.359 dB/year) was more negative than the observed mean RoP (-0.283, 95% CI = -0.299 to -0.268 dB/year), indicating a bias likely due to learning in standard LMMs. Conclusions: The distribution of "true" RoPs can be estimated with an exGaussian-LMM, improving model accuracy. Translational Relevance: We used these results to develop a fast and accurate analytical approximation for sample-size calculations in clinical trials using standard LMMs, which was integrated in a freely available web application.


Assuntos
Glaucoma , Campos Visuais , Humanos , Teorema de Bayes , Glaucoma/diagnóstico , Olho , Software
5.
Transl Vis Sci Technol ; 13(4): 17, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38591943

RESUMO

Purpose: To characterize the fundus tessellated density (FTD) in highly myopic glaucoma (HMG) and high myopia (HM) for discovering early signs and diagnostic markers. Methods: This retrospective cross-sectional study included hospital in-patients with HM (133 eyes) and HMG (73 eyes) with an axial length ≥26 mm at Zhongshan Ophthalmic Center. Using deep learning, FTD was quantified as the average exposed choroid area per unit area on fundus photographs in the global, macular, and disc regions. FTD-associated factors were assessed using partial correlation. Diagnostic efficacy was analyzed using the area under the curve (AUC). Results: HMG patients had lower global (0.20 ± 0.12 versus 0.36 ± 0.09) and macular FTD (0.25 ± 0.14 vs. 0.40 ± 0.09) but larger disc FTD (0.24 ± 0.11 vs. 0.19 ± 0.07) than HM patients in the tessellated fundus (all P < 0.001). In the macular region, nasal FTD was lowest in the HM (0.26 ± 0.13) but highest in the HMG (0.32 ± 0.13) compared with the superior, inferior, and temporal subregions (all P < 0.05). A fundus with a macular region nasal/temporal (NT) FTD ratio > 0.96 (AUC = 0.909) was 15.7 times more indicative of HMG than HM. A higher macular region NT ratio with a lower horizontal parapapillary atrophy/disc ratio indicated a higher possibility of HMG than HM (AUC = 0.932). Conclusions: FTD differs in degree and distribution between HMG and HM. A higher macular NT alone or with a lower horizontal parapapillary atrophy/disc ratio may help differentiate HMG. Translational Relevance: Deep learning-based FTD measurement could potentially assist glaucoma diagnosis in HM.


Assuntos
Aprendizado Profundo , Demência Frontotemporal , Glaucoma , Miopia , Humanos , Estudos Transversais , Estudos Retrospectivos , Glaucoma/complicações , Glaucoma/diagnóstico , Miopia/complicações , Miopia/diagnóstico , Atrofia , Corioide
6.
Transl Vis Sci Technol ; 13(4): 10, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38578635

RESUMO

Purpose: This study aims to determine whether OCT-derived rates of change in minimum rim width (MRW) are associated with and can potentially predict corresponding alterations in retinal nerve fiber layer thickness (RNFLT) in people with glaucoma. Methods: The rates of change between six-monthly visits were taken from 568 eyes of 278 participants in the P3 Study. Structural equation models (SEM) assessed whether one parameter was predicted by the concurrent or previous rate of the other parameter, after adjusting for its own rate in the previous time interval. Root mean square error of approximation (RMSEA, with 90% confidence intervals [CI]), Tucker Lewis index (TLI) and the comparative fit index (CFI) assessed goodness of fit. Results: Models without a time lag provided a better fit for the data (RMSEA = 0.101 [CI, 0.089, 0.113]), compared to a model featuring a time lag in RNFLT (RMSEA = 0.114 [CI, 0.102, 0.126]) or MRW (RMSEA = 0.114 [CI, 0.102, 0.127]). The SEMs indicated that rates for both MRW and RNFLT were predicted by their own rate in the previous time interval and by the other measure's change in the concurrent time interval (P > 0.001 for all). No evidence of a clinically significant time lag for either parameter was determined. Conclusions: MRW and RNFLT exhibit concurrent changes over time in patients with glaucoma, with no clinically significant time lag determined. Translational Relevance: RNFLT may be more useful than MRW in early glaucoma assessment because of its previously reported lower variability and reduced sensitivity to intraocular pressure changes.


Assuntos
Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Células Ganglionares da Retina , Fibras Nervosas , Retina , Glaucoma/diagnóstico , Tomografia de Coerência Óptica
7.
BMC Ophthalmol ; 24(1): 157, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594720

RESUMO

BACKGROUND: Aniridia is a rare eye disorder with a high incidence of glaucoma, and surgical intervention is often needed to control the intraocular pressure (IOP). Here, we reported a case of illuminated microcatheter-assisted circumferential trabeculotomy (MAT) performed on an aniridic glaucoma patient following a previous failed angle surgery. The surgical procedures for aniridic glaucoma were also reviewed. CASE PRESENTATION: A 21-year-old man, diagnosed with aniridic glaucoma, came to our hospital consulting for the poor control of left eye's IOP despite receiving goniotomy surgery 3 years ago. The IOP was 26 mmHg with maximum topical antiglaucoma eyedrops. The central cornea was opaque and the majority of iris was absent. The gonioscopy and ultrasound biomicroscopy (UBM) demonstrated that 360° anterior chamber angle was closed. The whole exome sequencing of peripheral blood confirmed a 13.39 Mb copy number loss at chromosome 11p15.1p13, containing PAX6 and WT1 gene. The 360° MAT surgery was performed on his left eye. At 1-year follow-up, the IOP was 19mmHg with 2 kinds of topical antiglaucoma medications, and the postoperative UBM demonstrated the successful incision of the anterior chamber angle. CONCLUSIONS: The case presented here exhibited a case of aniridic glaucoma treated by MAT surgery. The MAT surgery may be an effective option for IOP control in aniridic glaucoma patients following a previous failed angle surgery.


Assuntos
Aniridia , Glaucoma , Trabeculectomia , Masculino , Humanos , Adulto Jovem , Adulto , Trabeculectomia/métodos , Seguimentos , Resultado do Tratamento , Glaucoma/diagnóstico , Glaucoma/cirurgia , Pressão Intraocular , Gonioscopia , Estudos Retrospectivos , Fator de Transcrição PAX6
8.
BMC Ophthalmol ; 24(1): 168, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622519

RESUMO

INTRODUCTION: Corneal biomechanics has been implicated in a variety of ocular diseases. The purpose of this study was to evaluate the relationship between the glaucoma and corneal biomechanical properties, and exploring the value of corneal biomechanics in the diagnosis and follow-up of glaucoma diseases. METHODS: We searched studies in PubMed, EMBASE, Web of Science and clinicaltrials.gov., as of October 8, 2022. Only English studies were included, without publication time limit. We also searched the reference lists of published reviews. This meta-analysis was conducted with random-effects models, we used mean difference(MD) to evaluate the outcome, and the heterogeneity was assessed with the I2 statistic. Subgroup analyses were performed under the appearance of high heterogeneity. We used 11 items to describe the characteristics of included studies, publication bias was performed through the Egger's test. The quality assessment were evaluated by Newcastle-Ottawa Scale(NOS) items. RESULTS: A total of 27 eligible studies were identified for data synthesis and assessment. The result of meta-analysis showed that in the comparison of included indicators, the corneal biomechanics values of glaucoma patients were statistically lower than those of normal subjects in a similar age range. The covered indicators included central corneal thickness(CCT) (MD = -8.34, 95% CI: [-11.74, -4.94]; P < 0.001), corneal hysteresis(CH)(MD = -1.54, 95% CI: [-1.88, -1.20]; P < 0.001), corneal resistance factor(CRF)( MD = -0.82, 95% CI: [-1.21, -0.44]; P < 0.001), and intraocular pressure(IOP)( corneal-compensated intraocular pressure (IOPcc): MD = 2.45, 95% CI: [1.51, 3.38]; P < 0.001); Goldmann-correlated intraocular pressure (IOPg): MD = 1.30, 95% CI: [0.41, 2.20]; P = 0.004), they all showed statistical difference. While the value of axial length(AL) did not show statistically different(MD = 0.13, 95% CI: [-0.24, 0.50]; P = 0.48). CONCLUSION: Corneal biomechanics are associated with glaucoma. The findings can be useful for the design of glaucoma screening, treatment and prognosis.


Assuntos
Glaucoma , Humanos , Fenômenos Biomecânicos , Glaucoma/diagnóstico , Pressão Intraocular , Córnea , Tonometria Ocular
9.
Int Ophthalmol ; 44(1): 186, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643220

RESUMO

PURPOSE: This study introduces the Order of Magnitude (OM), a cost-effective, indigenous, virtual reality-based visual field analyzer designed for detecting glaucomatous visual field loss. METHODS: The OM test employs a two-step supra-thresholding algorithm utilizing stimuli of 0.43°diameter (equivalent to Goldmann size III) at low and high thresholds. A comparative analysis was conducted against the Humphrey visual field (HVF) test, considered the gold standard in clinical practice. Participants, including those with glaucoma and normal individuals, underwent comprehensive eye examinations alongside the OM and HVF tests between April and October 2019. Diagnostic sensitivity and specificity of the OM test were assessed against clinical diagnoses made by specialists. RESULTS: We studied 157 eyes (74 glaucomatous, 83 control) of 152 participants. Results demonstrated a high level of reliability for both OM and HVF tests, with no significant difference observed (P = 0.19, Chi-square test). The sensitivity and specificity of the OM test were found to be 93% (95% CI 86-100%) and 83% (95% CI 72.4-93%), respectively, while the HVF test showed sensitivity and specificity of 98% (95% CI 93.9-100%) and 83% (95% CI 73.9-92.8%), respectively. CONCLUSION: These findings suggest that the OM test is non-inferior to the reference standard HVF test in identifying glaucomatous visual field loss.


Assuntos
Glaucoma , Campos Visuais , Humanos , Reprodutibilidade dos Testes , Glaucoma/diagnóstico , Testes de Campo Visual/métodos , Transtornos da Visão/diagnóstico , Sensibilidade e Especificidade
10.
Transl Vis Sci Technol ; 13(4): 2, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564202

RESUMO

Purpose: Prior evidence suggests racial disparities in the utilization of visual field testing (VFT) for the diagnosis and monitoring of glaucoma. In this study, we considered the effect of baseline glaucoma severity and socioeconomic disadvantage along with other potential confounders such as test reliability, ancillary tests, and glaucoma surgeries on racial disparity in the frequency of VFT. Methods: The records of all subjects with a diagnosis of glaucoma who received VFT at an academic, tertiary care facility from January 2018 to December 2021 were accessed. Analysis was performed to compare VFT frequency, the total number of office visits (DoS), and the ratio of VFT frequency to DoS (VFT/DoS) across self-reported races while controlling for sex, age, socioeconomic disadvantage (Area Deprivation Index), VF reliability indicators and baseline mean deviation, optical coherence tomography frequency, and glaucoma surgeries. Results: Among the 2654 subjects (1515 White, 782 Black, and 357 Asian) included in this study, Black subjects had the worst socioeconomic status and disease severity at baseline. They also experienced a 3% lower VFT/DoS ratio compared to White subjects (P = 0.031). Asian subjects had a 5% lower VFT/DoS ratio compared to White subjects (P = 0.015). Discussion: We identified racial disparity in performing VFT in subjects with glaucoma even when multiple confounders were considered. Further investigation is necessary to identify other race-associated factors to work toward reducing racial disparities in VFT. Translational Relevance: Black and Asian subjects with glaucoma receive fewer VFT per visit compared to White subjects even when considering socioeconomic disadvantage and disease severity.


Assuntos
Glaucoma , Campos Visuais , Humanos , Reprodutibilidade dos Testes , Asiático , Glaucoma/diagnóstico , Tomografia de Coerência Óptica
11.
Medicina (Kaunas) ; 60(3)2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38541154

RESUMO

Glaucoma is one of the leading causes of irreversible blindness in the world. Early diagnosis and treatment increase the chances of preserving vision. However, despite advances in techniques for the functional and structural assessment of the retina, specialists still encounter many challenges, in part due to the different presentations of the standard optic nerve head (ONH) in the population, the lack of explicit references that define the limits of glaucomatous optic neuropathy (GON), specialist experience, and the quality of patients' responses to some ancillary exams. Computer vision uses deep learning (DL) methodologies, successfully applied to assist in the diagnosis and progression of GON, with the potential to provide objective references for classification, avoiding possible biases in experts' decisions. To this end, studies have used color fundus photographs (CFPs), functional exams such as visual field (VF), and structural exams such as optical coherence tomography (OCT). However, it is still necessary to know the minimum limits of detection of GON characteristics performed through these methodologies. This study analyzes the use of deep learning (DL) methodologies in the various stages of glaucoma screening compared to the clinic to reduce the costs of GON assessment and the work carried out by specialists, to improve the speed of diagnosis, and to homogenize opinions. It concludes that the DL methodologies used in automated glaucoma screening can bring more robust results closer to reality.


Assuntos
Glaucoma , Disco Óptico , Doenças do Nervo Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Glaucoma/diagnóstico , Doenças do Nervo Óptico/diagnóstico , Nervo Óptico , Programas de Rastreamento , Tomografia de Coerência Óptica
12.
Med J Malaysia ; 79(2): 206-211, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38553928

RESUMO

INTRODUCTION: Numerous tonometers are available to measure intraocular pressure (IOP) in children with glaucoma. This review aims to discuss IOP measurement techniques and principles and compare the accuracy, tolerability and ease of use of available tonometers in measuring IOP in paediatric glaucoma patients. MATERIALS AND METHODS: A review of observational studies was conducted to discuss the accuracy, tolerability and ease of use of tonometers in measuring IOP in children with glaucoma. RESULTS: Goldmann applanation tonometry (GAT) and its portable handheld versions remain the gold standard in measuring IOP. Tono-Pen (Reichert Ophthalmic Instruments, Depew, New York, USA) and rebound tonometer (RBT) both correlate well with GAT. Although both tonometers tend to overestimate IOP, Tono-Pen overestimates more than RBT. Overestimation is more remarkable in higher IOP and corneal pathologies (such as but not limited to scarred cornea and denser corneal opacity). RBT was better tolerated than other tonometers in children and was easier to use in children of all ages. CONCLUSIONS: RBT is the preferred tonometer for measuring IOP in children with glaucoma, as it is less traumatic, time efficient and does not require fluorescein dye or anaesthesia. However, examiners should use a second tonometer to confirm elevated IOP readings from the RBT.


Assuntos
Glaucoma , Pressão Intraocular , Criança , Humanos , Glaucoma/diagnóstico , Tonometria Ocular/métodos , Córnea , Manometria , Reprodutibilidade dos Testes
13.
Biosystems ; 238: 105156, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38428451

RESUMO

The early detection of some diseases can be a decisive factor in postponing or stabilizing their most adverse effects on the people who suffer from them. In the case of glaucoma, which is an ocular pathology that is the second leading cause of blindness in the world, early detection can make the difference between a patient's complete losses of vision, or preserve their sight, as well as improve their subsequent treatment. It is for this reason that there are currently medical campaigns for the early detection of pathologies with these characteristics in a certain study population, called screening, which have shown very good results. In addition, the application of telemedicine to these processes has allowed remote evaluation of cases by clinical experts and numerous initiatives have emerged for its use in new screening strategies. On the other hand, biomedical image processing techniques based on deep learning have undergone great development in recent years, and there are several works that have demonstrated their possible application in the automatic detection of glaucoma with fundus images. The article has consisted of the development of a web platform that integrates both scenarios: on the one hand, the remote evaluation of fundus images by medical specialists, and on the other, the application of a tool based on Deep Learning for the automatic detection of glaucoma in the case studies.


Assuntos
Aprendizado Profundo , Glaucoma , Humanos , Glaucoma/diagnóstico , Fundo de Olho , Processamento de Imagem Assistida por Computador
14.
BMJ Open ; 14(3): e082375, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38471693

RESUMO

INTRODUCTION: Glaucoma is the leading cause of irreversible blindness in the world. The need to diagnose glaucoma early in its natural history before extensive sight loss occurs cannot be overemphasised. However, glaucoma is largely asymptomatic in the early stages of the disease making it complex to diagnose clinically and requires the support of technology. The objective of this scoping review is to determine the nature and extent of the evidence for use of portable devices in the diagnosis of glaucoma. METHODS: We will consider studies conducted in all healthcare settings using portable devices for the detection of all type of adult glaucoma. We will also include any systematic reviews or scoping reviews, which relate to this topic. Searches will be conducted in MEDLINE, Embase, CENTRAL on the Cochrane Library and Global Health databases, from their inception to the present. Reference lists from publications identified in the searches will also be reviewed. Two authors will independently screen titles and abstracts, followed by full-text screening to assess studies for inclusion. Any disagreements will be discussed and resolved with a third author. Tables accompanied by narrative descriptions will be employed to discuss results and show how it relates to review questions. ETHICS AND DISSEMINATION: Ethical approval is not required in this review. Only published and publicly accessible data will be used. We will publish our findings in an open-access, peer-reviewed journal and develop an accessible summary of results and recommendations.


Assuntos
Glaucoma , Humanos , Cegueira/etiologia , Bases de Dados Factuais , Dissidências e Disputas , Glaucoma/diagnóstico , Instalações de Saúde , Projetos de Pesquisa , Literatura de Revisão como Assunto
15.
Clin Exp Optom ; 107(2): 122-129, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38467126

RESUMO

Detecting deterioration of visual field sensitivity measurements is important for the diagnosis and management of glaucoma. This review surveys the current methods for assessing progression that are implemented in clinical devices, which have been used in clinical trials, alongside more recent advances proposed in the literature. Advice is also offered to clinicians on what they can do to improve the collection of perimetric data to help analytical progression methods more accurately predict change. This advice includes a discussion of how frequently visual field testing should be undertaken, with a view towards future developments, such as digital healthcare outside the standard clinical setting and more personalised approaches to perimetry.


Assuntos
Glaucoma , Campos Visuais , Humanos , Testes de Campo Visual/métodos , Glaucoma/diagnóstico , Progressão da Doença , Transtornos da Visão/diagnóstico
16.
Clin Exp Optom ; 107(2): 107-109, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38467125
17.
Transl Vis Sci Technol ; 13(3): 10, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488433

RESUMO

Purpose: Compare estimated sensitivities of SITA-Standard to the RATA-Standard algorithm of the Radius virtual reality perimeter (VRP), and measure concordance in glaucoma staging. Methods: One hundred adult glaucoma patients-half with suspect or mild glaucoma, and half with moderate or severe-from five clinics performed four 24-2 visual field tests during a single visit, two with the Humphrey Field Analyzer (HFA) and two with Radius, in randomized order: HRHR or RHRH. Only one eye was tested per participant. We used the Wilcoxon rank sum test with Bonferroni correction to compare distributions of estimated sensitivities across all 54 test locations over the 15 to 40 dB measurement range of the Radius. Weighted kappa measured concordance in glaucoma staging between two masked glaucoma experts using Medicare definitions of severity. Results: A total of 62 OD and 38 OS eyes were tested. Estimated sensitivities for SITA-Standard and RATA-Standard were not significantly different for OD, but were for OS-likely because of SITA-Standard OD and OS being significantly different in our sample, but not for RATA-Standard. Low agreement was observed between 15 to 22 dB. Concordance in glaucoma staging was high for both graders: kappa = 0.91 and kappa = 0.93. Average test duration was 298 seconds for RATA-Standard and 341 seconds for SITA-Standard. The correlation in mean deviation was 0.94. Conclusions: Estimated sensitivities of RATA-Standard are comparable to SITA-Standard between 23 to 40 dB with high concordance in glaucoma staging. Translational Relevance: Radius VRP is statistically noninferior to HFA when staging glaucoma using Medicare definitions.


Assuntos
Glaucoma , Realidade Virtual , Dispositivos Eletrônicos Vestíveis , Idoso , Estados Unidos , Adulto , Humanos , Campos Visuais , Transtornos da Visão , Reprodutibilidade dos Testes , Medicare , Glaucoma/diagnóstico , Testes de Campo Visual/métodos
18.
Vestn Oftalmol ; 140(1): 93-98, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450472

RESUMO

Myopia and glaucoma are the leading causes of irreversible blindness in the world, and as the number of nearsighted people is predicted to increase sharply in the upcoming decades, an increase in combined pathology is expected. This article analyzes literature sources to assess the epidemiology of glaucoma and myopia both worldwide and in the Russian Federation, examine the anatomical changes of the eyeball associated with these diseases, and identify the diagnostic criteria that facilitate the verification of glaucoma when combined with myopia.


Assuntos
Glaucoma , Miopia , Humanos , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Glaucoma/etiologia , Miopia/complicações , Miopia/diagnóstico , Miopia/epidemiologia , Olho , Cegueira , Federação Russa/epidemiologia
19.
Zhonghua Yan Ke Za Zhi ; 60(3): 296-302, 2024 Mar 11.
Artigo em Chinês | MEDLINE | ID: mdl-38462381

RESUMO

Sleep apnea presents as recurrent respiratory arrests or shallow breathing during sleep, resulting in decreased oxygen saturation and sleep disruption. Among its various types, obstructive sleep apnea is the most common. Over the past few decades, the prevalence of sleep apnea has been on the rise, drawing increasing attention, particularly with the growing obesity and aging population. Prolonged exposure to a hypoxic environment due to sleep apnea not only damages multiple systems throughout the body but may also pose a threat to vision. Examining the relationship between sleep apnea and ocular diseases, along with exploring its pathogenesis, has become a prominent research topic in recent years. This article provides a comprehensive review of the existing literature concerning the correlation between sleep apnea and ocular diseases such as glaucoma, optic nerve diseases, retinal and choroidal diseases, and anterior eye segment diseases. In clinical practice, prioritizing early screening and treatment for sleep apnea is crucial to prevent the worsening of associated ophthalmic conditions.


Assuntos
Glaucoma , Doenças do Nervo Óptico , Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Humanos , Idoso , Síndromes da Apneia do Sono/complicações , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/diagnóstico , Glaucoma/diagnóstico
20.
J AAPOS ; 28(2): 103856, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38438075

RESUMO

PURPOSE: To identify patient characteristics associated with visit attendance, treatment outcomes, and optical coherence tomography (OCT) testing in pediatric glaucoma patients at an urban tertiary care center. METHODS: The records of patients with childhood glaucoma seen from 2015 to 2021 were reviewed. Primary outcomes were the proportion of scheduled visits completed, visual acuity and intraocular pressure (IOP) at most recent follow-up, and rates of OCT testing. Social determinants of health evaluated included race and ethnicity, distance of residence from clinic, insurance carrier type and residence within Baltimore City County, the latter two serving as proxies for socioeconomic status. RESULTS: A total of 99 patients met inclusion criteria: 61% were male; 47%, White (non-Hispanic); 25%, Black (non-Hispanic); 11%, Hispanic/Latino; and 7% Asian/Pacific Islander. Mean distance from clinic was 45.3 miles. Mean visit completion rate was 90.4%; there was no statistically significant variation in visit completion rates by patient characteristics. IOP outcomes did not vary across patient groups, but visual acuity outcomes in affected eyes were significantly worse among Baltimore City County residents compared with non-residents. Only 22% of the cohort received ≥1 OCT per year, and patients living 0-29.9 miles from clinic had significantly lower odds of reaching the threshold than more distant patients. Patients with state-based insurance had significantly lower odds of being ≥50th percentile for rate of OCTs received compared to patients with commercial insurance. CONCLUSIONS: In children with glaucoma, residence within Baltimore City County was associated with significantly worse visual acuity outcomes, and close proximity to clinic was an independent predictor of lower rates of OCT testing, despite similar visit attendance rates and IOP outcomes across all groups.


Assuntos
Glaucoma , Determinantes Sociais da Saúde , Criança , Humanos , Masculino , Feminino , Seguimentos , Centros de Atenção Terciária , Glaucoma/diagnóstico , Pressão Intraocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...